User Manual
Intel® NUC 11 Compute Element Product Specification
19
CAUTION
It is strongly recommended to make sure that the carrier board power source is disconnected
before installing or removing the Intel® NUC 11 Compute Element into the carrier board connector.
Installing or removing the Intel® NUC 11 Compute Element while a power source is connected to
the carrier board may cause damage to the Intel® NUC 11 Compute Element, operating system
corruption, create a no boot condition or result in data loss.
2.5 Wake Events
Table 8 and Table 9 lists the devices or specific events that can wake the computer from specific
states.
Table 8. Wake-Up Events
Wake-Up Event
Supported ACPI State
Comments
Power Button
S0, S0ix, S4, S5
RTC Alarm
S0, S0ix, S4, S5
Display to remain in sleep state
USB
S0, S0ix
Wake S4, S5 controlled by BIOS option
(not after G3)
AC Resume
S4, S5
PCIe
S0, S0ix, S4
Via WAKE; display to remain in sleep state
Wireless LAN
S0, S0ix
Display to remain in sleep state
Bluetooth*
S0, S0ix
Table 9. Wired LAN Wake-Up Events
Wake-Up Event
Supported ACPI State
Comments
225/226
S0ix, S4, S5
NetAdapterCx driver is needed; display to
remain in sleep state
219
S0ix and S5
Display to remain in sleep state
210/211
S5
Display to remain in sleep state