User’s Manual
2-22 Chapitre 2: Le BIOS
Memory Config uration
Memory Conguration
Bank Interleaving [Disabled]
Channel Interleaving [Auto]
Enable Clock to ALL DIMMs [Disabled]
MemCLK Tristate C3/ATLVID [Disabled]
Memory Hole Remapping [Enabled]
Unganged Mode support [Enabled]
Power Down Enable [Enabled]
Power Down Mode [Channel]
Enable Bank Memory
Interleaving
NorthBridge Configuration
2.4.3 Chipset
Le menu chipset vous permet de modier les paramètres avancés du chipset.
Choisissez un élément et pressez <Entrée> pour afcher le sous-menu.
Advanced Chipset Settings
WARNING: Setting wrong values in below sections
may cause system to malfunction.
NorthBridge Coguration
Internal Graphics
Memory Options &
Information
NorthBridge Chipset Conguration
Memory Conguration
DRAM Timing Conguration
Alternate VID [Auto]
Memory CLK :333 MHz
CAS Latency(Tcl) :5.0
RAS/CAS Delay(Trcd) :5 CLK
Row Precharge Time(Trp):5 CLK
Min Active RAS(Tras) :15 CLK
RAS/RAS Delay(Trrd) :3 CLK
Row Cycle (Trc) :21 CLK
Bank Interleaving [Disabled]
Dénit si les accès mémoire doivent être répartis sur des banques d’un
même noeud ou de plusieurs noeuds, diminuant ainsi la saturation des
accès. Options de conguration: [Disabled] [Auto]