User Manual

Table Of Contents
Software ROMB User Manual
24
Status – Shows the logical drive’s condition:
Functional – The logical drive is fully operational, and no problems are
present.
Critical – The logical drive is operational, but has lost its fault tolerance. For
RAID 1, 5, or 10, the logical drive contains a failed drive. You must identify
and replace the failed physical (disk) drive.
Offline – The logical drive is no longer operational and the RAID
Management Utility cannot rebuild it. You must identify and replace the failed
drives. Then you can create a new logical drive and copy your data to it from
your backup device.
Migrating – The logical drive is in the process of changing RAID levels and/
or adding one or more physical drives.
Synchronizing – The logical drive is in the process of checking and
correcting data and parity.
Rebuilding – The logical drive is in the process of repairing itself by
reconstructing the data on a failed or removed physical drive.
Initializing – A new logical drive is synchronizing its physical drives and
creating redundant data or parity data.
The BIOS screen displays the following information for JBOD Disks and Serial
ATAPI devices:
Port – SATA port to which the physical drive or Serial ATAPI device is connected.
Model Name – Manufacturer name and model of the drive or device