User Manual

Table Of Contents
Chapter 6: Technology
109
RAID 0
A RAID 0 source logical drive can migrate to the following target logical drives:
RAID 1
A RAID 1 Source logical drive can migrate to the following Target logical drives:
RAID 5
A RAID 5 Source logical drive can migrate to the following Target logical drives:
Target Requirements
RAID 0 Add physical drives.
RAID 1 2 physical drives only.
Only a single-drive RAID 0 can migrate to RAID 1 by adding 1
physical drive.
RAID 5 3 physical drives minimum, 6 maximum.
RAID 0 must have less than 6 physical drives.
RAID 10 4 physical drives minimum.
Even number of physical drives.
SPAN One drive only.
Target Requirements
RAID 0 None.
RAID 5 Add physical drives. 3 minimum, 6 maximum.
RAID 10 4 physical drives minimum.
Even number of physical drives.
Target Requirements
RAID 0 None.
RAID 5 Add physical drives. 6 maximum.