Extension Fan 1/2/3 Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum extension fan duty cycle. The
values range from 60% to 100%. When the CPU temperature is under the lower
limit, the extension fan operates at the minimum duty cycle.
Allow Fan Stop [Disabled]
Allows the fan to run at 0% duty cycle when the temperature of the source is
dropped below the lower temperature.
AIO PUMP Control [Disabled]
The subitems in this menu allows you to congure the AIO PUMP Control settings.
[PWM mode] Enables the Q-Fan control feature in PWM mode for the 4-pin AIO pump
fan.
[DC mode] Enables the Q-Fan control feature in DC mode for the 3-pin AIO pump fan.
[Disabled] Disables the Q-Fan control feature.
The following items appear only when you set the AIO PUMP Control to [PWM Mode] or
[DC Mode].
AIO PUMP Upper Temperature [70]
Use the <+> and <-> keys to adjust the upper limit of the AIO pump fan temperature. The
values range from 25ºC to 75ºC.
AIO PUMP Max. Duty Cycle(%) [100]
Use the <+> and <-> keys to adjust the maximum AIO pump fan duty cycle. The values range
from 20% to 100%. When the AIO pump fan temperature reaches the upper limit, the AIO
pump fan will operate at the maximum duty cycle.
AIO PUMP Middle Temperature [25]
Use the <+> or <-> keys to set the value for AIO pump fan’s middle temperature. The range
of the values depends on the AIO pump installed.
AIO PUMP Middle Duty Cycle(%) [20]
Use the <+> or <-> keys to adjust the AIO pump fan middle duty cycle. The values range
from 20% to 100%. When the AIO pump temperature reaches the upper limit, the AIO pump
fan operates at the maximum duty cycle.
AIO PUMP Lower Temperature [20]
Use the <+> or <-> keys to adjust the AIO pump fan’s lower temperature. The values range
from 20°C to 75°C.
AIO PUMP Min. Duty Cycle(%) [20]
Use the <+> and <-> keys to adjust the minimum AIO pump fan duty cycle. The values range
from 20% to 100%. When the AIO pump fan temperature is under the lower limit, the AIO
pump fan operates at the minimum duty cycle.