User Manual
Table Of Contents
- Safety information
- Chapter 1: Product Introduction
- Chapter 2: Hardware Setup
- 2.1 Chassis cover
- 2.2 Air ducts
- 2.3 Central Processing Unit (CPU)
- 2.4 System memory
- 2.5 Storage devices
- 2.6 Expansion slots
- 2.6.1 Installing an expansion card to the front PCIe riser card bracket (on select models)
- 2.6.2 Installing an ASUS PIKE II card
- 2.6.3 Installing an HBA/RAID card
- 2.6.4 Installing an expansion card to the rear left PCIe expansion card bracket (on select models)
- 2.6.5 Installing an expansion card to the rear right PCIe expansion card bracket (on select models)
- 2.6.6 Installing an OCP 3.0 card to the rear right OCP 3.0 socket board (on select models)
- 2.6.7 (optional) Installing the PFR module
- 2.7 Cable connections
- 2.8 Removable/optional components
- 2.9 Installing GPU cards
- 2.10 Installing Optional Kits
- Chapter 3: BIOS Setup
- 3.1 Managing and updating your BIOS
- 3.2 BIOS setup program
- 3.3 Main menu
- 3.4 Performance Tuning menu
- 3.5 Advanced menu
- 3.5.1 Trusted Computing
- 3.5.2 PSP Firmware Versions
- 3.5.3 Redfish Host Interface Settings
- 3.5.4 AMD CBS
- 3.5.5 APM Configuration
- 3.5.6 Serial Port Console Redirection
- 3.5.7 CPU Configuration
- 3.5.8 PCI Subsystem Settings
- 3.5.9 USB Configuration
- 3.5.10 Network Stack Configuration
- 3.5.11 CSM Configuration
- 3.5.12 NVMe Configuration
- 3.5.13 SATA Configuration
- 3.5.14 AMD Mem Configuration Status
- 3.5.15 Tls Auth Configuration
- 3.6 Chipset menu
- 3.7 Security menu
- 3.8 Boot menu
- 3.9 Tool menu
- 3.10 Save & Exit menu
- 3.11 Event Logs menu
- 3.12 Server Mgmt menu
- Chapter 4: Driver Installation
- Appendix
3-49
ASUS ESC8000A-E11
The following item appears only when Console Redirection is set to [Enabled].
Console Redirection Settings
These items become configurable only when you enable the Console Redirection
item. The settings specify how the host computer and the remote computer (which the
user is using) will exchange data. Both computers should have the same or compatible
settings.
Terminal Type [ANSI]
Allows you to set the terminal type.
[VT100] ASCII char set.
[VT100+] Extends VT100 to support color, function keys, etc.
[VT-UTF8] Uses UTF8 encoding to map Unicode chars onto 1 or more bytes.
[ANSI] Extended ASCII char set.
Bits per second [57600]
Selects serial port transmission speed. The speed must be matched on the other side.
Long or noisy lines may require lower speeds.
Configuration options: [9600] [19200] [38400] [57600] [115200]
Data Bits [8]
Configuration options: [7] [8]
Parity [None]
A parity bit can be sent with the data bits to detect some transmission errors. [Mark]
and [Space] parity do not allow for error detection.
[None] None
[Even] parity bit is 0 if the num of 1’s in the data bits is even
[Odd] parity bit is 0 if num of 1’s in the data bits is odd
[Mark] parity bit is always 1
[Space] parity bit is always 0
Stop Bits [1]
Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.)
The standard setting is 1 stop bit. Communication with slow devices may require more
than 1 stop bit.
Configuration options: [1] [2]
Flow Control [None]
Flow control can prevent data loss from buffer overflow. When sending data, if the
receiving buffers are full, a “stop” signal can be sent to stop the data flow. Once the
buffers are empty, a “start” signal can be sent to re-start the flow. Hardware flow
control uses two wires to send start/stop signals.
Configuration options: [None] [Hardware RTS/CTS]