User Manual

Table Of Contents
A-12
Appendix
Sensor No. Sensor Name
Event
Assertion Deassertion
0x38(56) TR11 Temperature Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x39(57) TR12 Temperature Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x3A(58) TR13 Temperature Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x3B(59) CPU2_DIMMI1_Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x3C(60) CPU2_DIMMI2_Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x3D(61) CPU2_DIMMJ1_Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x3E(62) CPU2_DIMMJ2_Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x3F(63) CPU2_DIMMK1_Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x40(64) CPU2_DIMMK2_Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x41(65) CPU2_DIMML1_Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x42(66) CPU2_DIMML2_Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x43(67) Riser01 Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x44(68) Riser02 Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x45(69) PCH Temperature Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x46(70) +48V Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x57(87) PCIE_Inlet_Temp Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x61(97) Outlet1 Temp /
CPU1_Inlet_Temp
Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
0x62(98) Outlet2 Temp /
CPU1_Outlet_Temp
Upper Non-critical - going high
Upper Critical - going high
Upper Non-critical - going high
Upper Critical - going high
(continued on the next page)
2. Voltage
Sensor No. Sensor Name
Event
Assertion Deassertion
0x66(102) +VCORE1 /
PVCCIN_CPU1 /
+VCORE0_CPU1
Upper Non-critical - going high
Upper Critical - going high
Lower Non-critical - going low
Lower Critical - going low
Upper Non-critical - going high
Upper Critical - going high
Lower Non-critical - going low
Lower Critical - going low
0x67(103) +VCORE2 /
PVCCIN_CPU2 /
+VCORE0_CPU2
Upper Non-critical - going high
Upper Critical - going high
Lower Non-critical - going low
Lower Critical - going low
Upper Non-critical - going high
Upper Critical - going high
Lower Non-critical - going low
Lower Critical - going low
0x68(104) +VDDQ_ABCD_CPU1 /
+VCCD_HV1
Upper Non-critical - going high
Upper Critical - going high
Lower Non-critical - going low
Lower Critical - going low
Upper Non-critical - going high
Upper Critical - going high
Lower Non-critical - going low
Lower Critical - going low
0x69(105) +VDDQ_EFGH_CPU1 Upper Non-critical - going high
Upper Critical - going high
Lower Non-critical - going low
Lower Critical - going low
Upper Non-critical - going high
Upper Critical - going high
Lower Non-critical - going low
Lower Critical - going low