User Manual
Table Of Contents
- Safety information
- Chapter 1: Product Introduction
- Chapter 2: Hardware Setup
- Chapter 3: Motherboard Information
- Chapter 4: BIOS Setup
- 4.1 Managing and updating your BIOS
- 4.2 BIOS setup program
- 4.3 Main menu
- 4.4 Performance Tuning menu
- 4.5 Advanced menu
- 4.5.1 Trusted Computing
- 4.5.2 AMD CBS
- 4.5.3 Onboard LAN Configuration
- 4.5.4 Serial Port Console Redirection
- 4.5.5 CPU Configuration
- 4.5.6 PCI Subsystem Settings
- 4.5.7 USB Configuration
- 4.5.8 Network Stack Configuration
- 4.5.9 NVMe Configuration
- 4.5.10 SATA Configuration
- 4.5.11 APM Configuration
- 4.5.12 AMD Mem Configuration Status
- 4.5.13 T1s Auth
- 4.5.14 Driver Health
- 4.6 Chipset menu
- 4.7 Security menu
- 4.8 Boot menu
- 4.9 Tool menu
- 4.10 Event Logs menu
- 4.11 Server Mgmt menu
- 4.12 Exit menu
- Chapter 5: Driver Installation
- Appendix
Chapter 2: Hardware Setup
2-44
4. Prepare the replacement PSU.
5. Align and insert the replacement PSU into the empty PSU bay until it clicks in place.
6. Reconnect the PSU power cable.
• The system automatically combines the two power supply modules as a single one.
The combined output power varies with input voltages. Refer to the table below for
details.
2600W
Input Voltage Max. Output Power (Watt) per PSU
100V-127Vac, 13.8A, 50-60Hz 1000W
240Vac, 16A, 50-60Hz 2600W
• To enable the hot-swap feature (redundant mode), keep the total power consumption
of the system under the maximum output power of an individual power supply module.
• Always use PSUs with the same watt and power rating. Combining PSUs with different
wattage (e.g. 1 x 1620 W + 1 x 2000 W) may yield unstable results and potential
damage to your system.
• For a steady power input, use only the power cables that come with the server system
package.