User Guide

Chapter 2: Hardware Setup
2-28
The system automatically combines the two power supply modules as a single one.
The combined output power varies with input voltages. Refer to the table below for
details.
1620W
Input Voltage Max. Output Power (Watt) per PSU
100V—120Vac, 12-10A, 50-60Hz 1000W
120V—140Vac, 12-10A, 50-60Hz 1200W
180V—240Vac, 10.5-8A, 50-60Hz 1620W
2000W
Input Voltage Max. Output Power (Watt) per PSU
100-120Vac, 12.7-10.5A, 50-60Hz 1100W
120-140Vac, 13.5-11.5A, 50-60Hz 1400W
200-220Vac, 10.0-9.5A, 50-60Hz 1800W
220-230Vac, 10.0-9.8A, 50-60Hz 1980W
230-240Vac, 10.0-9.8A, 50-60Hz 2000W
To enable the hot-swap feature (redundant mode), keep the total power consumption
of the system under the maximum output power of an individual power supply module.
Always use PSUs with the same watt and power rating. Combining PSUs with different
wattage (e.g. 1 x 1620 W + 1 x 2000 W) may yield unstable results and potential
damage to your system.
For a steady power input, use only the power cables that come with the server system
package.