User Guide

6-32
Chapter 6: RAID Conguration
3. Theutilityimmediatelystartsrebuildingafterthediskisselected.Whendone,the
status of the degraded RAID volume is changed to “Rebuild”.
4. Press<Esc>toexitIntelRapidStorageTechnologyandrebootthesystem.
5. Select
Start > Programs > Intel Rapid Storage > Intel Rapid Storage Console
orclicktheIntelRapidStorageTechnologytrayicontoloadtheIntelRapidStorage
Managerutility.
6. Fromthe
View
menu,select
Advanced Mode
to display the details of the Intel Rapid
StorageConsole.
7. FromtheVolumesviewoption,selectRAIDvolumetoviewtherebuildingstatus.When
nished,thestatusischangedto“Normal”.
Rebuilding the RAID with a new hard disk
IfanyoftheSATAharddiskdrivesincludedintheRAIDarrayfailed,thesystemdisplaysthe
statusoftheRAIDvolumeas“Degraded”duringPOST.Youmayreplacethediskdriveand
rebuild the RAID array.
TorebuildtheRAIDwithanewharddisk:
1. RemovethefailedSATAharddiskandinstallanewSATAharddiskofthesame
specicationintothesameSATAPort.
Selectadestinationdiskwiththesamesizeastheoriginalharddisk.
2. Reboot the system then follow the steps in section
Rebuilding the RAID with other
non-RAID disk
.
[ESC]-Exit [ENTER]-Select Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION]
RAID Volumes: *=Data is Encrypted
ID Name Level1 Strip Size Status Bootable
1 Volume0 RAID1(Mirror) N/A 149.0GB Rebuild Yes
Physical Devices:
Port Drive Model Serial # Size Type/Status(Vol ID)
1 ST3160812AS 9LS0F4HL 149.0GB Member Disk(0)
2 ST3160812AS 3LS0JYL8 149.0GB Member Disk(0)
Volumes with “Rebuild” status will be rebuilt within the operating system.
3. Reset Disks to Non-RAID
4. Exit
1. Create RAID Volume
2. Delete RAID Volume