User's Manual

ASUS ASMB8-iKVM
4-21
PEF Management LAN Destination Page
This page is used to congure the Event lter, Alert Policy and LAN destination. A sample
screenshot of PEF Management LAN Destination Page is given below.
The elds of PEF Management – LAN Destination Tab are explained below.
1.
LAN Destination:
Displays Destination number for the newly congured entry (read-
only).
2.
Destination Type:
Destination type can be either an SNMP Trap or an Email alert.
For Email alerts, the 3 elds - destination Email address, subject and body of the
message needs to be lled. The SMTP server information also has to be added - under
Conguration->SMTP. For SNMP Trap, only the destination IP address has to be lled.
3.
Destination Address:
If Destination type is SNMP Trap, then enter the IP address of
the system that will receive the alert. Destination address will support the following:
- IPv4 address format.
- IPv6 address format.
If Destination type is Email Alert, then give the email address that will receive the email.
4.
Subject & Message:
These elds must be congured if email alert is chosen as
destination type. An email will be sent to the congured email address in case of any
severity events with a subject specied in subject eld and will contain the message
eld's content as the email body.
5.
Add:
To save the new LAN destination and return to LAN destination list.
6.
Cancel:
To cancel the modication and return to LAN destination list.