User's Manual
5-8 Chapter 5: RAID conguration
8. Select
Units
from the
Virtual Drive
sub-menu, and then press <Enter>.
9. Select the units for virtual drive size from the menu, and then press <Enter>.
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
D N L I N
D N L I N
LSI Software RAID Conguration Utility Ver C.05 Apr 5, 2012
BIOS Version A.10.09231523R
E a s y C o n f i g u r a t i o n - A R R A Y
Virtual Drive(s) Congured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64 KB ONLINE
Virtual Drive 0
RAID = 1
Units= MB
Size = 152146MB
DWC = Off
RA = On
Accept
SPAN = NO
Select Units For VD Size
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option
Select Units For VD Size
MB
GB
TB
10. When creating a
RAID 1
or a
RAID 10
set, select
DWC
from the
Virtual Drive
menu,
and then press <Enter>.
When creating a
RAID 0
set, proceed to step 12.
11. Select
On
to enable the
Disk Write Cache
setting, and then press <Enter>.
Enabling DWC can improve the performance, but with the risk of data loss.
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
D N L I N
D N L I N
E a s y C o n f i g u r a t i o n - A R R A Y
LSI Software RAID Conguration Utility Ver C.05 Apr 5, 2012
BIOS Version A.10.09231523R
Virtual Drive(s) Congured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64 KB ONLINE
Virtual Drive 0
RAID = 1
Units= MB
Size = 152146MB
DWC = Off
RA = On
Accept
SPAN = NO
Disk Write Cache Setting Of VD
Change DWC
Off
On
Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option