User's Manual

5-6 Chapter 5: RAID conguration
3. Select all the drives required for the RAID set, and then press <F10> to congure array
setting.
4. Press <Space> to select the congurable array.
2. The
ARRAY SELECTION MENU
displays the available drives connected to the SATA
ports. Use the up/down arrow keys to select the drives you want to include in the RAID
set, and then press <Space>. When selected, the drive indicator changes from
READY
to
ONLIN A[X]-[Y]
, where X is the array number, and Y is the drive number.
The information of the selected hard disk drive displays at the bottom of the screen.
You need at least two identical hard disk drives when creating a RAID 1 set.
You need at least four identical hard disk drives when creating a RAID 10 set.
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
Port # 2 DISK 74.74GB HDS728080PLA380 05.01C05
Easy Conguration - ARRAY SELECTION MENU
PORT #
ONLIN A00-00
ONLIN A00-01
READY
READY
0
1
LSI Software RAID Conguration Utility Ver C.05 Apr 5, 2012
BIOS Version A.10.09231523R
SPACE-Sel,ENTER-EndArray,F10-Congure,F2-Drive Info,F3-Virtual Drives,F4-HSP
2
3
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
D N L I N
D N L I N
Easy Conguration - ARRAY SELECTION MENU
Select Congurable Array(s)
A-0
SPAN-1
LSI Software RAID Conguration Utility Ver C.05 Apr 5, 2012
BIOS Version A.10.09231523R
Cursor Keys, SPACE-(De)Select F2-ChIdInfo F3-SlotInfo F10-Congure Esc-Quit