User Manual
Table Of Contents
- Safety information
- Chapter 1: Product Introduction
- Chapter 2: Hardware Information
- 2.1 Chassis cover
- 2.2 Air duct
- 2.3 Central Processing Unit (CPU)
- 2.4 System memory
- 2.5 Storage devices
- 2.5.1 Installing an E1.S module (for E1.S module SKU only)
- 2.5.2 Removing an E1.S module (for E1.S module SKU only)
- 2.5.3 Installing an external 2.5” storage device (on selected models)
- 2.5.4 Removing an external 2.5” storage device (on selected models)
- 2.5.5 Installing an internal 2.5” storage device (only for 650W/Short PSU models)
- 2.5.6 Removing an internal 2.5” storage device (only for 650W/Short PSU models)
- 2.6 Expansion slot
- 2.7 Cable connections
- 2.8 Removable/optional components
- 2.9 Rail Kit Options
- Chapter 3: Motherboard Information
- Chapter 4: BIOS Setup
- 4.1 Managing and updating your BIOS
- 4.2 BIOS setup program
- 4.3 Main menu
- 4.4 Performance Tuning menu
- 4.5 Advanced menu
- 4.5.1 Trusted Computing
- 4.5.2 ACPI Settings
- 4.5.3 Redfish Host Interface Settings
- 4.5.4 Onboard LAN Configuration
- 4.5.5 UEFI Variables Protection
- 4.5.6 Serial Port Console Redirection
- 4.5.7 SIO Configuration
- 4.5.8 PCI Subsystem Settings
- 4.5.9 USB Configuration
- 4.5.10 Network Stack Configuration
- 4.5.11 NVMe Configuration
- 4.5.12 APM Configuration
- 4.5.13 Tls Auth Configuration
- 4.5.14 Intel(R) Virtual RAID on CPU
- 4.5.15 Third-party UEFI driver configurations
- 4.6 Platform Configuration menu
- 4.7 Socket Configuration menu
- 4.8 Security menu
- 4.9 Boot menu
- 4.10 Tool menu
- 4.11 Event Logs menu
- 4.12 Server Mgmt menu
- 4.13 Exit menu
- Appendix
4-12
The following items appear only when Redfish is set to [Enabled].
Authentication mode [Basic Authentication]
Allows you to select the authentication mode.
Configuration options: [Basic Authentication] [Session Authentication]
IP address
Allows you to enter the IP address.
IP Mask address
Allows you to enter the IP Mask address.
IP Port
Allows you to enter the IP Port.
4.5.4 Onboard LAN Configuration
4.5.5 UEFI Variables Protection
The items in this submenu will differ depending on the LAN controller installed on the system.
Onboard X710 LAN Configuration
Intel X710 LAN1 and LAN2
LAN Enable [LAN1, LAN2 Enabled]
Allows you to enable or disable the Intel LAN.
Configuration options: [Disabled] [LAN1 Enabled only] [LAN1, LAN2 Enabled]
Password protection of Runtime Variables [Disable]
Control the NVRAM Runtime Variable protection through System Admin Password.
Configuration options: [Enable] [Disable]