User Manual
Report No. ASL23051710
73 - 95
Universal Standard Service, Inc.
EN 62368-1, GROUP DIFFERENCES
Clause
Requirement + Test
Result - Remark
Verdict
G.7.2
Ireland and United Kingdom
To the first paragraph the following is added:
A power supply cord with a conductor of 1,25 mm
2
is allowed for equipment which is rated over 10 A
and up to and including 13 A.
N/A
ZC
ANNEX ZC, NATIONAL DEVIATIONS (EN)
N/A
10.5.2
Germany
The following requirement applies:
For the operation of any cathode ray tube intended
for the display of visual images operating at an
acceleration voltage exceeding 40 kV, authorization
is required, or application of type approval
(Bauartzulassung) and marking.
Justification:
German ministerial decree against ionizing
radiation (Röntgenverordnung), in force since
2002-07-01, implementing the European Directive
96/29/EURATOM.
NOTE Contact address:
Physikalisch-Technische Bundesanstalt, Bundesallee 100,
D-38116 Braunschweig,
Tel.: Int +49-531-592-6320,
Internet: http://www.ptb.de
N/A
ZD
ANNEX ZD, IEC AND CENELEC CODE DESIGNATIONS FOR FLEXIBLE CORDS
N/A
Type of flexible
Code designations
IEC
CENELEC
PVC insulated cords
Flat twin tinsel cord
60227 IEC 41
H03VH-Y
Light polyvinyl chloride sheathed flexible cord
60227 IEC 52
H03VV-F
H03VVH2-F
Ordinary polyvinyl chloride sheathed flexible cord
60227 IEC 53
H05VV-F
H05VVH2-F
Rubber insulated cords
Braided cord
60245 IEC 51
H03RT-F
Ordinary tough rubber sheathed flexible cord
60245 IEC 53
H05RR-F
Ordinary polychloroprene sheathed flexible cord
60245 IEC 57
H05RN-F
N/A