Universal Standard Service, Inc.
EN 62368-1, GROUP DIFFERENCES
Clause
Requirement + Test
Result - Remark
Verdict
of 1,5 kV r.m.s., 50 Hz or 60 Hz, for 1 min.
Translation to Norwegian (the Swedish text will also
be accepted in Norway):
“Apparater som er koplet til beskyttelsesjord via
nettplugg og/eller via annet jordtilkoplet utstyr og
er tilkoplet et koaksialbasert kabel-TV nett, kan
forsake brannfare. For å unngå dette skal det
ved tilkopling av apparater til kabel-TV nett
installeres en galvanisk isolator mellom apparatet
og kabel-TV nettet.”
Translation to Swedish:
”Apparater som är kopplad till skyddsjord via jordat
gguttag och/eller via annan utrustning och
samtidigt är kopplad till kabel-TVt kan i vissa fall
medfőra risk főr brand. Főr att undvika detta skall
vid anslutning av apparaten till kabel-TVt
galvanisk isolator finnas mellan apparaten och
kabel-TV nätet.”.
5.7.6.2
Denmark
To the end of the subclause the following is added:
The warning (marking safeguard) for high touch
current is required if the touch current or the
protective current exceed the limits of 3,5 mA .
N/A
B.3.1 and B.4
Ireland and United Kingdom
The following is applicable:
To protect against excessive currents and short-
circuits in the primary circuit of direct plug-in
equipment, tests according to Annexes B.3.1 and
B.4 shall be conducted using an external miniature
circuit breaker complying with EN 60898-1, Type B,
rated 32A. If the equipment does not pass these
tests, suitable protective devices shall be included
as an integral part of the direct plug-in
equipment, until the requirements of Annexes
B.3.1 and B.4 are met
N/A
G.4.2
Denmark
To the end of the subclause the following is added:
Supply cords of single phase appliances having a
rated current not exceeding 13 A shall be provided
with a plug according to DS 60884-2-D1:2011.
CLASS I EQUIPMENT provided with socket-outlets with
earth contacts or which are intended to be used in
locations where protection against indirect contact is
required according to the wiring rules shall be provided
with a plug in accordance with standard sheet DK 2-1a or
DK 2-5a.
If a single-phase equipment having a RATED CURRENT
N/A