User Manual

Report No. ASL23051710
59 - 95
Universal Standard Service, Inc.
pin9 to GND
(Jumper on
COM1_SEL1,
pin(1-2))
Output
shutdown. No
hazard. No
damage.
ASRE.
COM (COM2),
pin9 to GND
(Jumper on
COM2_SEL1,
pin(1-2))
Overload
36Vdc
See table
5.4.1.4
--
--
See
table
5.4.1.4
See
table
5.4.1.4
NT. NC. CT.
Normal
operation. No
hazard. No
damage.
Open circuit
voltage=12.0
4Vdc,
Maximum
available
current=1500
mA. ASRE.
COM (COM2),
pin9 to GND
(Jumper on
COM2_SEL1,
pin(1-2))
Short
36Vdc
30mins.
--
--
--
--
NT. NC.
Output
shutdown. No
hazard. No
damage.
ASRE.
Supplementary information:
Test table is provided to record abnormal and fault conditions for all applicable energy sources including
Thermal burn injury. Column “Abnormal/Fault.” Specify if test condition by indicating “Abnormal” then the
condition for a Clause B.3 test or “Single Fault” then the condition for Clause B.4.
Results Key: NB=No indication of dielectric breakdown; NC=Cheesecloth remained intact; NT=Tissue paper
remained intact; IP=Internal protection operated (list component); CD=Components damaged (list damaged
components); @=Tests were repeated 2 more times (Totally 3 times) and get the same result; I/P=Input;
O/P=Output, NSF=No Ignition; TC=Touch Current measured; ASRE=All Safeguards remain effective
All temperature measurement refer to appended table 5.4.1.4.
For COM port: Take 12Vdc output as worst case to test.
B.4
TABLE: Fault condition tests
N/A
Ambient temperature (C) ............................................................. :
Power source for EUT: Manufacturer, model/type, output rating .. :
Component No.
Fault
Condition
Supply
voltage, (V)
Test time
(ms)
Fuse
no.
Fuse
current, (A)
T-couple
Temp.
(C)
Observation
Supplementary information:
Results Key: NB=No indication of dielectric breakdown; NC=Cheesecloth remained intact; NT=Tissue paper
remained intact; IP=Internal protection operated (list component); CD=Components damaged (list damaged