User Manual

Report No. ASL23051710
57 - 95
Universal Standard Service, Inc.
continuous data transmission.
B.3
TABLE: Abnormal operating condition tests
P
Ambient temperature (C) ............................................................. :
See below or 25C
Power source for EUT: Manufacturer, model/type, output rating .. :
See appended table 4.1.2
Component No.
Abnormal
Condition
Supply
voltage, (V)
Test time
(ms)
Fuse
no.
Fuse
current, (A)
T-couple
Temp.
(C)
Observation
--
--
--
--
--
--
--
--
Maximum
load at output
terminals
(B.3.5)
--
--
--
--
--
--
--
--
Motherboard:
MB1
USB
(USB32G2_12),
pin1,10 to GND
Overload
36Vdc
See table
5.4.1.4
--
--
See
table
5.4.1.4
See
table
5.4.1.4
NT. NC. CT.
Normal
operation. No
hazard. No
damage.
Open circuit
voltage=5.06
Vdc,
Maximum
available
current=2200
mA. ASRE.
USB
(USB32G2_12),
pin1,10 to GND
Short
36Vdc
30mins.
--
--
--
--
NT. NC.
Output
shutdown. No
hazard. No
damage.
ASRE.
USB
(USB32G2_34),
pin1,10 to GND
Overload
36Vdc
See table
5.4.1.4
--
--
See
table
5.4.1.4
See
table
5.4.1.4
NT. NC. CT.
Normal
operation. No
hazard. No
damage.
Open circuit
voltage=5.06
Vdc,
Maximum
available
current=2100
mA. ASRE.
USB
(USB32G2_34),
pin1,10 to GND
Short
36Vdc
30mins.
--
--
--
--
NT. NC.
Output
shutdown. No
hazard. No
damage.