User Manual

Report No. ASL23051710
51 - 95
Universal Standard Service, Inc.
Test condition 2: Maximum normal load 36Vdc (Horizontal), Duration: 2hrs.20mins.
Test condition 3: Maximum normal load 36Vdc (Wall mounted, Power button side faced downward), Duration:
1hr.55mins.
Test condition 4: Maximum normal load 36Vdc (Wall mounted, Power button side faced to left), Duration:
1hr.32mins.
Test condition 5: Maximum normal load 36Vdc (Wall mounted, Power button side faced to right), Duration:
1hr.38mins.
Test condition 6: Maximum normal load 36Vdc (Wall mounted, Power button side faced upward), Duration:
2hrs.19mins.
Test condition 7: Maximum load at output terminal, Duration: 1hr.39mins.
Test condition 8: Maximum load at output terminal, Duration: 1hr.40mins.
All abnormal test conditions with maximum normal load 36Vdc (Horizontal).
Temperature T of winding:
t
1
C)
R
1
()
t
2
C)
R
2
()
T (C)
Allowed
T
max
(C)
Insulation
class
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Supplementary information:
Note 1: Tma should be considered as directed by appliable requirement.
Note 2: Tma is not included in assessment of Touch Temperatures (Clause 9).
1. Temperature is confirmed by thermal scanner.
5.4.1.8
TABLE: Working voltage measurement
N/A
Location
RMS voltage
(V)
Peak voltage
(V)
Frequency
(Hz)
Comments
Supplementary information:
5.4.1.10.2
TABLE: Vicat softening temperature of thermoplastics
N/A
Penetration (mm) ................................................................ :
Object/ Part No./Material
Manufacturer/t
rademark
T softening (°C)
supplementary information: