User Manual

Report No. ASL23051710
37 - 95
Universal Standard Service, Inc.
EN 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
M.9.1
Protection from electrolyte spillage
N/A
M.9.2
Tray for preventing electrolyte spillage
N/A
M.10
Instructions to prevent reasonably foreseeable
misuse (Determination of compliance: inspection,
data review; or abnormal testing) ....................... :
Complied by inspection and data
review.
P
N
ELECTROCHEMICAL POTENTIALS
N/A
Metal(s) used ....................................................... :
O
MEASUREMENT OF CREEPAGE DISTANCES AND CLEARANCES
N/A
Figures O.1 to O.20 of this Annex applied .......... :
P
SAFEGUARDS AGAINST ENTRY OF FOREIGN OBJECTS AND SPILLAGE OF
INTERNAL LIQUIDS
P
P.1
General requirements
P
P.2.2
Safeguards against entry of foreign object
P
Location and Dimensions (mm) ......................... :
Openings do not exceed 5 mm in any
dimension or 1 mm in width.
P.2.3
Safeguard against the consequences of entry of
foreign object
N/A
P.2.3.1
Safeguards against the entry of a foreign object
N/A
Openings in transportable equipment
N/A
Transportable equipment with metalized plastic
parts .................................................................... :
N/A
P.2.3.2
Openings in transportable equipment in relation to
metallized parts of a barrier or enclosure
(identification of supplementary safeguard) ....... :
N/A
P.3
Safeguards against spillage of internal liquids
N/A
P.3.1
General requirements
N/A
P.3.2
Determination of spillage consequences
N/A
P.3.3
Spillage safeguards
N/A
P.3.4
Safeguards effectiveness
N/A
P.4
Metallized coatings and adhesive securing parts
N/A
P.4.2 a)
Conditioning testing
N/A
Tc (°C) ................................................................. :
Tr C) .................................................................. :
Ta (°C) ................................................................. :