User Manual

Report No. ASL23051710
29 - 95
Universal Standard Service, Inc.
EN 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
G.2.3
Relay controlling connectors supply power
N/A
G.2.4
Mains relay, modified as stated in G.2
N/A
G.3
Protection Devices
P
G.3.1
Thermal cut-offs
N/A
G.3.1.1a)
&b)
Thermal cut-outs separately approved according
to IEC 60730 with conditions indicated in a) & b)
N/A
G.3.1.1c)
Thermal cut-outs tested as part of the equipment
as indicated in c)
N/A
G.3.1.2
Thermal cut-off connections maintained and
secure
N/A
G.3.2
Thermal links
N/A
G.3.2.1a)
Thermal links separately tested with IEC 60691
N/A
G.3.2.1b)
Thermal links tested as part of the equipment
N/A
Aging hours (H) .................................................. :
Single Fault Condition ........................................ :
Test Voltage (V) and Insulation Resistance () . :
G.3.3
PTC Thermistors
P
G.3.4
Overcurrent protection devices
N/A
G.3.5
Safeguards components not mentioned in G.3.1 to G.3.5
N/A
G.3.5.1
Non-resettable devices suitably rated and marking
provided
N/A
G.3.5.2
Single faults conditions ........................................ :
N/A
G.4
Connectors
P
G.4.1
Spacings
N/A
G.4.2
Mains connector configuration ........................... :
N/A
G.4.3
Plug is shaped that insertion into mains socket-
outlets or appliance coupler is unlikely
P
G.5
Wound Components
N/A
G.5.1
Wire insulation in wound components ................
N/A
G.5.1.2 a)
Two wires in contact inside wound component,
angle between 45° and 90°
N/A
G.5.1.2 b)
Construction subject to routine testing
N/A
G.5.2
Endurance test on wound components
N/A
G.5.2.1
General test requirements
N/A
G.5.2.2
Heat run test
N/A
Time (s) ............................................................... :