User Manual
Report No. ASL23051710
20 - 95
Universal Standard Service, Inc.
EN 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
6.4.8.3.1
Fire enclosure and fire barrier openings
P
6.4.8.3.2
Fire barrier dimensions
P
6.4.8.3.3
Top Openings in Fire Enclosure: dimensions (mm)
................................................................................. :
Openings do not exceed 5 mm in
any dimension or 1 mm in width.
When antenna connector not
installed:
Antenna hole is covered by rubber
with V-1 minimum material.
P
Needle Flame test
N/A
6.4.8.3.4
Bottom Openings in Fire Enclosure, condition met
a), b) and/or c) dimensions (mm) ......................... :
Openings do not exceed 3 mm in any
dimension or 1 mm in width.
Bottom opening is cover by sponge
with V-1 minimum material.
P
Flammability tests for the bottom of a fire
enclosure ............................................................... :
N/A
6.4.8.3.5
Integrity of the fire enclosure, condition met: a), b)
or c) ................................................................... :
N/A
6.4.8.4
Separation of PIS from fire enclosure and fire
barrier distance (mm) or flammability rating ......... :
N/A
6.5
Internal and external wiring
P
6.5.1
Requirements
VW-1 wires used, which considered
to equivalent to IEC/TS 60695-11-
21.
P
6.5.2
Cross-sectional area (mm
2
) .................................. :
See sub-clause 6.5.1.
⎯
6.5.3
Requirements for interconnection to building wiring
.............................................................................. :
N/A
6.6
Safeguards against fire due to connection to
additional equipment
P
External port limited to PS2 or complies with Clause
Q.1
Output complied with Annex Q.1.
P
7
INJURY CAUSED BY HAZARDOUS SUBSTANCES
P
7.2
Reduction of exposure to hazardous substances
N/A
7.3
Ozone exposure
N/A
7.4
Use of personal safeguards (PPE)
N/A
Personal safeguards and instructions ............... :
⎯
7.5
Use of instructional safeguards and instructions
N/A
Instructional safeguard (ISO 7010) ................... :
⎯
7.6
Batteries ............................................................. :
(See Annex M)
P