User Manual
Report No. ASL23051710
18 - 95
Universal Standard Service, Inc.
EN 62368-1
Clause
Requirement + Test
Result - Remark
Verdict
Multiple connections to mains (one connection at a
time/simultaneous connections) .......................... :
⎯
5.7.4
Earthed conductive accessible parts ................... :
N/A
5.7.5
Protective conductor current
N/A
Supply Voltage (V) .............................................. :
⎯
Measured current (mA) ....................................... :
⎯
Instructional Safeguard ....................................... :
N/A
5.7.6
Prospective touch voltage and touch current due
to external circuits
N/A
5.7.6.1
Touch current from coaxial cables
N/A
5.7.6.2
Prospective touch voltage and touch current from
external circuits
N/A
5.7.7
Summation of touch currents from external circuits
N/A
a) Equipment with earthed external circuits
Measured current (mA) ....................................... :
N/A
b) Equipment whose external circuits are not
referenced to earth. Measured current (mA) ....... :
N/A
6
ELECTRICALLY- CAUSED FIRE
P
6.2
Classification of power sources (PS) and potential ignition sources (PIS)
P
6.2.2
Power source circuit classifications
See ENERGY SOURCE
IDENTIFICATION AND
CLASSIFICATION TABLE for details.
P
6.2.2.1
General
P
6.2.2.2
Power measurement for worst-case load fault ... :
See appended table 6.2.2.
P
6.2.2.3
Power measurement for worst-case power source
fault ....................................................................... :
N/A
6.2.2.4
PS1 ...................................................................... :
See 6.2.2
P
6.2.2.5
PS2 ...................................................................... :
See 6.2.2
P
6.2.2.6
PS3 ...................................................................... :
See 6.2.2
P
6.2.3
Classification of potential ignition sources
All conductors and devices are
considered as Resistive PIS, except
PS1.
P
6.2.3.1
Arcing PIS ........................................................... :
N/A
6.2.3.2
Resistive PIS ....................................................... :
See 6.2.3
P
6.3
Safeguards against fire under normal operating and abnormal operating conditions
P
6.3.1 (a)
No ignition and attainable temperature value less
than 90 % defined by ISO 871 or less than 300 C
(See appended table 5.4.1.4, 6.3.2,
9.0, B.2.6)
P