Computer Hardware User Manual
Table Of Contents
- DSEB-D16 Series specifications summary
- Typography
- About this guide
- Safety information
- Notices
- Product introduction
- Hardware information
- Powering up
- BIOS setup
- RAID configuration
- 5.1 Setting up RAID
- 5.2 LSI Software RAID Configuration Utility
- 5.2.1 Creating a RAID 0 or RAID 1 set
- 5.2.2 Creating a RAID 10 set
- 5.2.3 Adding or viewing a RAID configuration
- 5.2.4 Initializing the logical drives
- 5.2.5 Rebuilding failed drives
- 5.2.6 Checking the drives for data consistency
- 5.2.7 Deleting a RAID configuration
- 5.2.8 Selecting the boot drive from a RAID set
- 5.2.9 Enabling the WriteCache
- 5.3 Intel® Matrix Storage Manager Option ROM Utility
- 5.4 Global Array Manager
- 5.5 LSI Logic MPT Setup Utility (DSEB-D16/SAS model only)
- Driver installation
- Reference information

5-46 Chapter 5: RAID conguration
4. The
Select New Array Type
screen apprears.
Use the arrow keys to select
Create IS Volume
, then press <Enter>.
5. The
Create New Array
screen shows the disks you can add to make up
the IS volume. Use the arrow key to select a disk, then move the cursor to
the RAID Disk column. To include this disk in the array, press <+>, <->, or
<Space>.
By default, the RAID Disk eld shows No before array creation. This eld is
grayed out under the following conditions:
• The disk does not meet the minimum requirements for use in a RAID array.
• The disk is not large enough to mirror existing data on the primary drive.
• The disk has been selected as the Hot Spare for the RAID array.
• The disk is already part of another array.
Esc = Exit Menu F1/Shift+1 = Help
Enter = Choose array type to create
LSI Logic Cong Utility v6.18.00.00 (2007.08.07)
Select New Array Type -- SAS1068
Create IM Volume Create Integrated Mirror Array of 2
disks plus an optional hot spare. Data
on the primary disk may be migrated.
Create IME Volume Create Integrated Mirrored Enhanced
Array of 3 to 8 disks including an
optional hot spare.
ALL DATA
on array disks will be DELETED!
Create IS Volume Create Integrated Striping array of
2 to 8 disks.
ALL DATA
on array disks will be DELETED!
Esc = Exit Menu F1/Shift+1 = Help
SPACE/+/- = Select disk for array or hot spare C = Create array
LSI Logic Cong Utility v6.18.00.00 (2007.08.07)
Create New Array -- SAS1068
Array Type: IS
Array Size(MB): 102996
Slot Device Identier RAID Hot Drive Pred Size
Num Disk Spr Status Fail (MB)
0 SEAGATE ST373454SS 0003 [Yes] [NO] ------- ---- 70007
1 SEAGATE ST373454SS 0003
[NO] [NO] ------- ---- 70007
2 SEAGATE ST373454SS 0003
[Yes] [NO] ------- ---- 35003
3 SEAGATE ST373454SS 0003
[Yes] [NO] ------- ---- 35003