User’s Manual

4-30 Chapter 4: BIOS setup
Scroll down to display more items:
F1 Help
↑↓
Select Item -/+ Change Values F9 Setup Defaults
ESC Exit
→←
Select Menu Enter Select Sub-Menu F10 Save and Exit
Item Specic Help
Full fan speed will
be started when the
temperature reaches the
selected target value.
Hardware Monitor
SYSTEM1 Target Temperature [70
o
C]
SYSTEM2 Target Temperature [70
o
C]
FBD_FAN1 Speed
4272 RPM
VCORE0 Voltage 1.21 V
VCORE1 Voltage N/A
VTT 1.22 V
+1.5V 1.48 V
+1.8V 1.82 V
+3V 3.34 V
+12V 12.28 V
+5V 5.11 V
+5VSB 5.11 V
VBAT 3.15 V
PhoenixBIOS Setup Utility
Advanced
CPU1/2 Domain 0/1 Temperature (CPU1/2 Target Temperature),
SYSTEM1/2 Temperature, CPU_FAN1/2 Speed, FRN_FAN1/2/3/4
Speed, REAR_FAN1/2 Speed
These elds show the auto-detected values and are not user-congurable. If no
CPU or fan is installed, the eld shows N/A.
Smart Fan Control [Smart Fan II]
Allows you to select the fan speed control mode.
Conguration options: [Disabled] [Smart Fan] [Smart Fan II]
CPU1/2 Domain 0/1 Target Temperature
(CPU1/2 Target Temperature)
Allows you to set the target CPU temperature at which the CPU fan will start
running if the fan is not yet turned on. Conguration options: [54 ºC]~[76 ºC]
SYSTEM1/2 Target Temperature
Allows you to set the target sytem temperature at which the system fan will start
running if the fan is not yet turned on. Conguration options: [49 ºC]~[70 ºC]
FBD_FAN1 Speed, VCORE0/1 Voltage, VTT, +1.5V, +1.8V, +3V, +12V,
+5V, +5VSB, VBAT
These elds show the auto-detected values and are not user-congurable.