Specifications
DS300f G2 Series User Manual
61
uPDatInG fIrmware on a raID SubSyStem
Usethisfunctiontoash(update)thermwareontheASUSDS300fG2.
Download the latest rmwareimagelefromASUSStoragesupport:
http://www.ASUS Storage.com/support/ and save it to your Host PC or TFTP server.
Important
Verify that no background activities are running on the RAID subsystem.
ToupdatethermwareontheRAIDsubsystemandJBODexpansionunits:
1. Click the Administration tab.
2. Click the Firmware Update icon.
3. Click the Controller Firmware Update tab.
The Controller Firmware Update screen appears showing the current Image Version Number and Build
Date.
4. Choose a download option:
•
LocalFilethroughHTTP–ClicktheBrowsebutton,locatethermware
imagele,clicktheletochooseit,thenclicktheOpenbutton.
• TFTPServer–EntertheTFTPServerhostnameorIPaddress,portnumberandlename.
5. Optional. Check the Non-disruptive Image Update (NDIU) box.
NDIUupdatestheRAIDcontrollersandI/Omodulesoneatatime,enablingI/Ooperationscontinue
duringthermwareupdate.Updateswiththisoptiontakealongerperiodoftimetocomplete.OnlyASUS
DS300fG2modelssupportthisfeature.
6. Click the Next button.
ThenextscreenshowstheFlashImage(rmwareimagele)VersionNumberandBuildDate.
7. Click the Submit button.
The progress of the update displays.
Warning
DoNOTpowerofftheRAIDsubsystemduringtheupdate!
DoNOTmovetoanyotherscreenuntilthermwareupdateoperationis
completed!
Whentheupdateiscompletedamessagetellsyoutorebootthesubsystem,
8. Click the OK button.
•
IfyouchosetheDisruptiveFlashMethod,theRAIDsubsystem
andJBODexpansionunitsautomaticallyrestart.
• IfyouchosetheNon-DisruptiveFlashMethod,thesystemautomatically
ashesandrestartstheRAIDcontrollersoneatatime.
AutoMAtic restArt
IfyoudidNOTchecktheNDIUbox,theRAIDsubsystemandJBODexpansionunitsautomaticallyrestart.That
action temporarily disrupts I/O operations and drops your ASUS Storage Management connection.
To reestablish your ASUS Storage Management connection:
1. Wait no less than two minutes.
2. Click LogoutintheASUSStorageManagementHeader,thenloginagain.
Ifyoucannotlogin,wait30secondsandtryagain.
3. Inyourbrowser,clickLogoutintheASUSStorageManagementHeader,thenloginagain.
Ifyoucannotloginimmediately,wait30secondsandtryagain.