raId Controller probleMs
RAID controller problems include:
• "Maintenance Mode" on page 211
• "Finding and Correcting the Cause of the Problem" on page 211
• "Taking a RAID Controller out of Maintenance Mode" on page 211
• "Unsaved Data in the Controller Cache" on page 212
Controllerproblemsoccurwhenoneofthecontrollersgoesintomaintenancemode.
maIntenance moDe
ForASUSDS300fG2swithtwoRAIDcontrollers,oneofthementersmaintenance mode in the event of:
• A difference of some kind between the two controllers (described below)
• An internal controller failure
Whenacontrollerentersmaintenancemode,itgoesofineanditdisplaysN/A (not accessible) under Readiness
Status.
Youmustndandcorrectthecauseoftheproblemandthentakethecontrolleroutofmaintenancemode.
fInDInG anD correctInG the cauSe of the Problem
externAl checks
MakethefollowingexternalcheckstoyourASUSDS300fG2subsystem.Besurethat:
• BothRAIDcontrollersarepresent,fullyinsertedintotheirslots,andlockedintoplace.
• TheRAIDcontrollersmatch,meaningbothareFibreChannelorbothareiSCSI.
• All SAS expansion cables from the RAID controllers to external JBOD units in good condition and are
securelyconnected.
Important
A disconnected SAS expansion cable causes the two RAID controllers to see a different
setofcongureddrives.Thisconditionisthemostcommoncauseofacontrollerentering
maintenancemode.
internAl checks
IfallexternalchecksareOK,takethefollowingactions:
1. ShutdowntheASUSDS300fG2.
2. RemoveoneoftheRAIDcontrollers.
See“ReplacingaRAIDController–DualControllers”onpage180.
3. RestarttheASUSDS300fG2.
4. AftertheASUSDS300fG2isfullybooted,viewthecontrollerinformation.
Seepage60(ASUSStorageManagement)orpage124(CLU).
5. Observeandrecordthefollowinginformationabouttherstcontroller:
• SDRAMmemorysize
• Hardwareversion
• Firmwareversion
6. ShutdowntheASUSDS300fG2.
7. Removetherstcontrollerandinstallthesecondcontroller.
8. Repeatsteps3through6.Thencompareyourrecords.
9. Correctanydifferencesbetweenthetwocontrollers.
See "Updating the Subsystem Firmware" on page <?>.
takInG a raID controller out of maIntenance moDe
IfyoushutdowntheASUSDS300fG2subsystemintheprocessofcorrectingthemaintenancemodeproblem,
the affected RAID controller boots into normal modewhentheASUSDS300fG2restarts.Nofurtheractionis
required.
If you corrected the problem without shutting down the ASUS DS300f G2 subsystem, choose one of the
following methods to take the controller out of maintenance mode:
• Restart the ASUS DS300f G2 subsystem
• Establishaserialconnection,thenusetheCLI
• EstablishaTelnetconnection,thenusetheCLI