Specifications
DS300f G2 Series User Manual
206
checkInG comPonent InStallatIon
Tocheckacomponent’sinstallation,removethecomponent,thenreinstallthecomponentinitsoriginallocation.
Inmostcases,thisactionxesabadconnectionandallowsASUSDS300fG2todetectthecomponent.Ifthis
actiondoesnotcorrecttheproblem,replacetheunit.
OnASUSDS300fG2swithdualcontrollers,whenonecontroller’sStatusLEDisamberandtheothercontroller’s
StatusLEDisashingred,itmeansthatthecontrollerwiththeashingredLEDhasenteredmaintenancemode.
See "RAID Controller Problems" on page 211.
IftheControllerStatusLEDcontinuestodisplayamberafterstartup,contactASUSStorageTechnicalSupport.
See "Contacting Technical Support" on page <?>.
TheDirtyCacheLEDashesduringinput/outputoperation.IftheLEDshinesamberandthepowerisoff,there
isunsaveddatainthecache.DoNOTpowerdowntheASUSDS300fG2whilethisLEDison.
Clu reports a probleM
The CLUreportsinformationpassively,thatisyoumustdeterminewhichfunctionstocheckbasedonthesound
oftheASUSDS300fG2’saudiblealarmandanyamberorredLEDs.SeeASUS DS300f G2 is Beeping5 andLEDs
Display Amber or Red7formoreinformation.
Checktheeventlogsrst.Thencheckthereportedcomponent.
vIewInG runtIme eventS
To display Runtime Events:
1. FromtheMainMenu,highlightEventViewerandpressEnter.
ThelogofRuntimeEventsappears.Eventsareaddedtothetopofthelist.Eachitemincludes:
• Sequence number–Beginswith0atsystemstartup.
• Device–DiskArray,LogicalDrive,PhysicalDrivebyitsIDnumber.
• Severity–SeetheTablebelow.
• Timestamp–Dateandtimetheeventhappened.
• Description–Adescriptionoftheeventinplainlanguage.
2. Presstheupanddownarrowkeystoscrollthroughthelog.
Event Severity Levels
Level Description
Fatal
Non-recoverableerrororfailurehasoccurred.
Critical
Actionisneedednowandtheimplicationsoftheconditionareserious.
Major
Actionisneedednow.
Minor
Actionisneededbuttheconditionisnotaseriousatthistime.
Warning
Usercandecidewhetherornotactionisrequired.
Information
Informationonly,noactionisrequired.