Specifications
DS300f G2 Series User Manual
9
General speCIfICatIons
Power suPPlies
• Hot swap and redundant with PFC, 100-240 Vac auto-ranging, 50 -60 Hz, N+1 design. Meets 80Plus bronze.
voltAge
• 100-240 VAC
• Auto-Ranging
current (MAxiMuM)
• 4 A @ 115 VAC
• 2 A @ 230 VAC
Power conversion efficiency
• >80% @ 110V (>20% load)
• >80% @ 240V (>20% load)
oPerAting environMent
teMPerAture rAnge
• Operational:5°to35°C(41°to95°F)
• Non-Operational: -40° to 60°C (-40° to 140°F)
huMidity rAnge
• Operational:10%to90%(Non-Condensing)
• Non-Operational:5%to95%(Non-Condensing)
noise, shock, And vibrAtion
Acoustic noise levels
• Typical: 55 dB
• Maximum: 75 dB
shock
• Operational: 5G, 11 ms duration
• Non-Operational: 30G, 11ms duration
vibrAtion
• Operational: 0.2G, sinewave, 0.5 oct/min, 5 to 500 Hz
• Non-Operational: 1G, 5 to 500 Hz
diMensions
(Height, Width, Depth)
• 131x447x507mm(5.2x17.6x19.96in)
weight
• 31.3kg/69lbs(withdrivesinstalled)
• 20.1 kg / 44.3 lbs (without drives installed)