Specifications
DS300f G2 Series User Manual
128
4. Highlight Voltage Sensors and press Enter.
If any voltage is outside the Healthy Threshold values, there is a voltage malfunction in the enclosure.
See "Diagnosing an Enclosure Problem" on page <?>.
vIewInG battery InformatIon (clu)
This feature enables you monitor and recondition the subsystem battery or batteries.
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
4. Highlight Batteries and press Enter.
5. Highlight the battery you want to monitor and press Enter.
bAttery notes
Ifabatterydoesnotreectnormalconditionsanditisnotcurrentlyunderreconditioning,runtheRecondition
function before you replace the battery. See Reconditioning a Battery (CLU).
Reconditioning fully discharges, then fully recharges the battery. During reconditioning, if the Adaptive Writeback
Cache function is enabled, the controller cache is set to Write Thru. After reconditioning, the cache is reset to
Write Back. See "Making Controller Settings (CLU)" on page 124.
If a battery reaches the threshold temperature while charging or discharging, the charge or discharge pauses
and the blower runs at high speed until the battery temperature falls below the threshold.
If the battery does not maintain normal values after a Recondition, replace the battery. See "Replacing a Cache
Backup Battery" on page <?>.
reconDItIonInG a battery (clu)
To recondition the subsystem battery:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
4. Highlight Batteries and press Enter.
5. Highlight the battery you want to recondition and press Enter.
6. Highlight Start Reconditioning and press Enter.
7. PressYtoconrm.
Reconditioning fully discharges, then fully recharges the battery. During reconditioning, if the Adaptive
Writeback Cache function is enabled, the controller cache is set to Write Thru. After reconditioning, the
cache is reset to Write Back. See "Making Controller Settings (CLU)" on page 124.
locatInG an encloSure (clu)
This feature helps you identify the physical ASUS DS300f G2 enclosure you are working with through the CLU.
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
4. Highlight Locate Enclosure and press Enter.
The LEDs on the front of the ASUS DS300f G2 blink for one minute.