Specifications
DS300f G2 Series User Manual
127
vIewInG fru vPD InformatIon (clu)
FRU VPD refers to Vital Product Data (VPD) information about Field Replaceable Units (FRU) in the enclosure.
The number and type of FRU depends on the subsystem model.
To view FRU VPD information:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
4. Highlight FRU VPD Information and press Enter.
Use this information when communicating with Technical Support and when ordering replacement units.
For contact information, see "Contacting Technical Support" on page <?>.
vIewInG Power SuPPly StatuS (clu)
To view the status of the power supplies:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
4. Highlight Power Supplies and press Enter.
The screen displays the operational and fan status of ASUS DS300f G2’s three power supplies. If any
status differs from normal or the fan speed is below the Healthy Threshold value, there is a fan/power
supply malfunction. See "Replacing a Power Supply" on page <?>.
locatInG a Power SuPPly (clu)
To locate a power supply:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
4. Highlight Power Supplies and press Enter.
5. Highlight Locate Power Supply and press Enter.
The LED on the selected power supply blinks for one minute.
vIewInG coolInG unIt StatuS (clu)
To view the status of the power supply fans:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
4. Highlight Cooling Units and press Enter.
The screen displays the status and speed of ASUS DS300f G2’s cooling units, which are the power supply
fans. If fan speed is below the Healthy Threshold, there is a malfunction.
vIewInG temPerature SenSor StatuS (clu)
To view the status of the temperature sensors:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
4. Highlight Temperature Sensors and press Enter.
If any temperature exceeds the Healthy Threshold value, there is an overheat condition in the enclosure.
See Making Enclosur e Settings (CLU) and see "Diagnosing an Enclosure Problem" on page <?>.
vIewInG voltaGe SenSor StatuS (clu)
To view the status of the voltage sensors:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.