Specifications
DS300f G2 Series User Manual
126
ManaGInG the enClosure (Clu)
Enclosure Management includes the following functions:
• "Viewing the Enclosures Summary (CLU)" on page 126
• "Viewing Enclosure Information (CLU)" on page 126
• "Making Enclosur e Settings (CLU)" on page 126
• "Viewing Power Supply Status (CLU)" on page 127
• "Locating a Power Supply (CLU)" on page 127
• "Viewing Cooling Unit Status (CLU)" on page 127
• "Viewing Temperature Sensor Status (CLU)" on page 127
• "Viewing Voltage Sensor Status (CLU)" on page 127
• "Viewing Battery Information (CLU)" on page 128
• "Locating an Enclosure (CLU)" on page 128
vIewInG the encloSureS Summary (clu)
Enclosure Management includes information, status, settings and location. To access Enclosure Management:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
The following information is shown:
•
EnclosureIDnumber
• EnclosureType
• OperationalStatus
• StatusDescription(speciccomponentsinneedofattention,ifany)
vIewInG encloSure InformatIon (clu)
To view enclosure information:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
You can monitor power supplies, cooling units, enclosure temperatures and voltages, and the battery.
AdJustAble iteMs
You can set or adjust the following items:
• Enclosure Warning and Critical temperature thresholds
• Controller Warning and Critical temperature thresholds
See “Making Enclosure Settings” below.
For information on Enclosure problems, see "Enclosure Problems" on page <?>.
makInG encloSur e SettInGS (clu)
To make Enclosure settings:
1. From the Main Menu, highlight Subsystem Management and press Enter.
2. Highlight Enclosure Management and press Enter.
3. Highlight the enclosure you want and press Enter.
4. Highlight Enclosure Settings and press Enter.
5. Highlight the Temperature Warning threshold you want to change.
6. Press the backspace key to erase the current value.
7. Type a new interval value in degrees C.
8. Press Control-A to save your settings.