PreParInG a DISk array for tranSPort
This feature prepares the physical drives that make up the disk array to be removed from the enclosure and
installed in a different location.
To prepare a disk array for transport:
1. Click the Storage tab.
2. Click the Disk Array icon.
The list of disk arrays appears.
3. Clickthediskarrayyouwant,thenclicktheTransport button.
4. Click the Conrm button.
The status changes to Transport Ready.
5. Remove the physical drives and install them in their new location.
Formoreinformation,see“InstallingPhysicalDrives”onpage16.
rebuIlDInG a DISk array
When you rebuildadiskarray,youareactuallyrebuildingthedataononephysicaldrive.
If there is no spare drive of adequate capacity and the AutoRebuildfunctionisDISABLED,youmustreplace
the failed drive with an uncongured physical drive, then perform a Manual Rebuild. See "Making Rebuild
Settings" on page 76.
Important
Ifyourreplacementdiskdrivewasformerlypartofadifferentdiskarrayorlogicaldrive,you
mustclearthecongurationdataonthereplacementdrivebeforeyouuseit.See"Clearing a
Stale or a PFA Condition" on page 90.
PerforMing A MAnuAl rebuild
To perform a manual rebuild:
1. Click the Administration tab.
2. Click the Background Activities icon.
The list of background activities appears.
3. Mouse-over Rebuild and click the Start button.
4. FromtheSourcePhysicalDrivedrop-downmenu,chooseaSourcediskarrayandphysicaldrive.
Arrays have an ID No. Physical drives have a Seq. No.(sequence number)
5. FromtheTargetPhysicalDrivedrop-downmenu,chooseaTargetphysicaldrive.
6. Click the Conrm button.
When the disk array is rebuilding:
•
Thediskarrayshowsagreencheck iconandRebuildingstatus.
• Logicaldrivesunderthediskarraycontinuetoshowayellow! iconandCriticalstatus.
stoPPing, PAusing or resuMing A rebuild
Tostop,pauseorresumeaRebuild:
1. Click the Administration tab.
2. Click the Background Activities icon.
The list of background appears.
3. Mouse-over Rebuild and click the Stop,Pause,orResume button.