Service manual

Part No. 39528 Genie GS-1530 & Genie GS-1930 7 - 5
Service Manual - First Edition Section 7 - Repair Procedures
DIP Switch Function Definitions
Motion Beacon: The motion beacon option flashes
only when operating a function.
Motion Alarm: The motion alarm will beep when
operating any function.
Lift/Drive Cut Out: This cuts out lift and drive
functions when the machine goes out of level.
Required for Europe and Australia.
Overload: This cuts out lift when the cylinder is
overloaded. Required for France.
Descent Delay: This option halts descent for 4
seconds at approximately 6 feet (2 m). Required for
Europe.
DIP Switch Code Chart
A mark in the column indicates that the machine
configuration includes this option.
PLATFORM CONTROLS
Diagnostic
Display Code
Dip Switch
Code
Motion Beacon
Motion Alarm
Lift Drive Cut Out
Overload Cutout
Descent Delay
00 00000000
01 00000100
02 00001000
03 00010000
04 00100000
05 01000000
06 00001100
••
07 00010100
••
08 00100100
••
09 01000100
••
10 00011100
•••
11 00101100
••
12 01001100
••
13 00110100
••
14 01010100
•••
15 01100100
••
16 00111100
••••
17 01011100
•••
18 01101100
••
19 01110100
•••
20 01111100
•••••
21 00011000
••
22 00101000
••
23 01001000
••
24 00111000
•••
25 01011000
••
26 01101000
••
27 01111000
••••
28 00110000
••
29 01010000
••
30 01110000
•••
31 01100000
••