Service manual

Part No. 39528 Genie GS-1530 & Genie GS-1930 7 - 3
Service Manual - First Edition Section 7 - Repair Procedures
PLATFORM CONTROLS
1-2
Software Configuration
The ECM (Electronic Control Module) contains
programming for all configurations of the GS-1530
and GS-1930. The platform controls can be
adjusted to a different configuration by changing the
combination of the DIP switch settings. The DIP
switch is located on the circuit board inside the
platform control box.
DIP switches have two positions - ON or OFF. When
reading the DIP switch code in the
DIP Switch
Code Chart
, the ON and OFF are represented by the
numbers 1 (ON) and 0 (OFF).
Select a test area that is firm, level
and free of obstructions.
Models before serial number 17408
were not adjustable when they
were shipped from the factory. If
the ECM (Electronic Control
Module) has been updated to
revision "b0" or later, or if the
model's serial number is after
17407, you can access the
revision level of the ECM by using
the following procedure:
How to Determine the Revision
Level
1 Remove the platform controls from the
platform.
2 Turn the key switch to platform control and pull
out the Emergency Stop buttons to the ON
position at both the ground and platform
controls.
3 Press and hold the lift enable button and the
function enable switch. Move the joystick
handle to the UP position to raise the platform.
Observe the code shown in the LED display
window, located on the battery pack side of the
machine.
Result: The configuration code of the DIP
switch will appear in the LED display window.
4 Press and hold the lift enable button and the
function enable switch. Move the joystick
handle to the DOWN position to lower the
platform. Observe the code shown in the LED
display window, located on the battery pack
side of the machine.
Result: The software revision level will appear
in the LED display window. If revision level "b0"
appears in the display window, the procedure
under
How to Set the DIP Switch Codes
on the
next page will apply. If revision level "A" is
displayed, the procedure will not apply.
5 Push in the Emergency Stop button to the OFF
position at both the ground and platform
controls and turn the key switch to the OFF
position.