Service manual

5 - 22 Genie GS-1530 & Genie GS-1930 Part No. 39528
Service Manual - First EditionSection 5 - Troubleshooting Flow Charts
CHART 8
Install a 0 to 2000 psi
pressure gauge at the
quick disconnect
coupling on the function
manifold and activate
the steer left function.
1200
psi
less than
1200 psi
Repair or replace the
steer cylinder OR
replace the steer left/
right valve cartridge OR
the function manifold
could have an internal
defect. Consult the
Genie Industries Service
Department.
Check for mechanical
restrictions keeping the
steer left function from
moving OR repair or
replace the steer
cylinder OR consult the
Genie Industries Service
Department.
Continued from the
previous page.
Reset the steer relief
valve pressure (item C)
on the function manifold
to 1200 psi OR replace
the relief valve.
1200 psi