Test the Emergency Stop Buttons
Properly functioning Emergency Stop buttons
are essential for safe machine operation. An
improperly operating Emergency Stop button
will fail to shut off power and stop all machine
functions resulting in a hazardous situation.
As a safety feature, selecting
and operating the ground controls
will override the platform controls,
except the platform Emergency
Stop button.
1 Turn the key switch to ground control and pull
out the Emergency Stop button to the ON
position at both the ground and platform
controls.
2 Push in the Emergency Stop button at the
ground controls to the OFF position.
Result: No functions should operate.
3 Turn the key switch to platform control and pull
out the Emergency Stop button to the ON
position at both the ground and platform
controls.
4 Push down the Emergency Stop button at the
platform controls to the OFF position.
Result: No machine functions should operate.
The ground control Emergency
Stop button will stop all machine
operation, even if the key switch
is switched to platform control.
B-6
Test the Horn
A functioning horn is essential to safe machine
operation. The horn is activated at the platform
controls and sounds at the ground as a warning to
ground personnel. An improperly functioning horn
will prevent the operator from alerting ground
personnel of hazards or unsafe conditions.
1 Turn the key switch to platform control and
pull out the Emergency Stop button to the
ON position at both the ground and
platform controls.
2 Push down the horn button at the platform
controls.
Result: The horn should sound.