User Guide

Overview A-9
Version 1.0 Copyright © 2001-2003 by LSI Logic Corporation. All rights reserved.
137 4 An automatic
rebuild has started
on logical drive.
A physical disk failed and a spare
device was available. A spare physi-
cal disk was found and replaced the
failed device.
None.
138 4 A manual rebuild
has started on
logical drive.
Client started the rebuild on user's
request. User replaced the failed
device and 'Raidbld' started the
rebuild.
None.
139 4 Rebuild on logical
drive is over.
Rebuild completed successfully only
for this logical drive.
None.
140 3 Rebuild on logical
drive is cancelled.
User cancelled rebuild. Higher priority
rebuild started.
Restart the rebuild if
required.
141 2 Rebuild stopped
with error.
Due to an unknown error on the con-
troller rebuild failed.
Try rebuild again.
142 2 Rebuild stopped
with error. New
device failed.
New physical device failed. New
physical device is not compatible with
MDAC hardware/firmware.
Replace the new
device.
143 2 Rebuild stopped
because logical
drive failed.
At least one more physical disks
failed in the array.
It may not be possible
to recover from this
error. Contact your ser-
vice representative.
144 4 Logical drive ini-
tialization started.
User started the initialization. Any
previous data is lost.
None.
145 4 Logical drive ini-
tialization done.
Initialize operation completed
successfully.
None.
146 3 Logical drive ini-
tialization
cancelled.
User cancelled the initialization. Restart initialization if
required.
147 2 Logical drive ini-
tialization failed.
One/multiple physical device(s) failed.
Controller has been removed. Con-
troller has been powered off.
Refer to the device fail-
ure event.
Table A.2 GAM TT Events for PCI Controllers (Cont.)
ID Severity Description Details Actions
(Sheet 8 of 16)