User Guide

A-6 Event Information
Version 1.0 Copyright © 2001-2003 by LSI Logic Corporation. All rights reserved.
41 1 A physical disk
failed because of
busy status or par-
ity error.
The device returned busy status. The
SCSI transaction with the device met
with parity error.
Replace physical disk
and rebuild it.
42 1 A physical disk set
to failed state by
host.
Command from host set the Physical
disk to failed state.
Replace physical disk
and rebuild it.
43 1 A physical disk
failed because
access to the
device met with a
selection time out.
Device disconnected or powered off.
Bad device.
Replace physical disk
and rebuild it. Check
power and cabling.
44 1 A physical disk
failed because of
a sequence error
in the SCSI bus
phase handling.
Physical disk failure. Replace physical disk
and rebuild it.
45 1 A Physical disk
failed because
device returned an
unknown status.
Bad Physical disk or incompatible
device.
Replace Physical disk
or the device and
rebuild it.
46 1 A Physical disk
failed because
device is not
ready.
Device not spinning, just turned bad.
Power to the device failed.
Replace Physical disk
and rebuild it. Check
power and rebuild
device.
47 1 A Physical disk
failed because
device was not
found on start up.
Device not connected. Device not
responding. Clear configuration sus-
pend mode command was invoked.
Check setup. Check
the startup option
parameters on the
system.
48 1 A Physical disk
failed because
write operation of
the 'Configuration
On Disk' failed.
Bad Physical disk. Device write
protected.
Replace Physical disk
and rebuild it. Check
the startup option
parameters on the
system.
Table A.2 GAM TT Events for PCI Controllers (Cont.)
ID Severity Description Details Actions
(Sheet 5 of 16)