User Manual

4-76
Chapter 4: Redfish Technology Pack
Name Type ReadOnly Description
Description String True
Provides description of the resource. Refer to section 4.3.3 Resource.
Temperatures Array of
Objects
False
This is the definition for temperature sensors. Refer to Table 35
Temperature Properties.
Fans Array of
Objects
False
This is the definition for fans. Refer to Table 37 Fan Properties.
Redundancy(N)(C) Array True This structure is used to show redundancy for fans. The Component ids
will reference the members of the redundancy groups.
Please refer to section
4.4 Redfish AMI OEM Entities
for
Redundancy information that can be configured through
System Builder.w
Table 35 Temperature Properties
Name Type ReadOnly Description
Name(C) String True The name of the Temperature sensor.
SensorNumber(C) Number True A numerical identifier for this temperature sensor that is unique within
this resource.
Status Object True
Refer to section 4.3.3 Resource for Resource.Oem.
ReadingCelsius Number True The current value of the temperature sensor’s reading.
UpperThreshold
NonCritical(C)
Number True The current reading is above the normal range but is not critical. Units
shall use the same units as the related ReadingCelsius property.
UpperThreshold
Critical(C)
Number True The current reading is above the normal range but is not yet Fatal. Units
shall use the same units as the related ReadingCelsius property.
UpperThreshold
Fatal(C)
Number True The current reading is above the normal range and is fatal. Units shall
use the same units as the related ReadingCelsius property.
LowerThreshold
NonCritical(C)
Number True The current reading is below the normal range but is not critical. Units
shall use the same units as the related ReadingCelsius property.
LowerThreshold
Critical(C)
Number True The current reading is below the normal range but is not yet fatal. Units
shall use the same units as the related ReadingCelsius property.
LowerThreshold
Fatal(C)
Number True The value of this property shall indicate the present reading is below the
normal range and is fatal. Units shall use the same units as the related
ReadingCelsius property.
MinReadingRange
Temp
Number True The lowest possible value for CurrentReading. Units shall use the same
units as the related ReadingCelsius property.
MaxReadingRange
Temp
Number True The highest possible value for CurrentReading. Units shall use the
same units as the related ReadingCelsius property.
PhysicalContext(C) Object True The affected device or region within the chassis to which
this Temperature measurement applies. Refer to Table 36
ThermalPhysicalContextEnum Properties.
This property can be configured through system builder. If
it is not configured then the default value will be set to this
property. i.e., Room
RelatedItem(C) Array True The ID(s) of the resources associated with this Power Limit.
E16160_ASMB9-iKVM_UM_V3.indb 76E16160_ASMB9-iKVM_UM_V3.indb 76 1/17/2020 2:29:30 PM1/17/2020 2:29:30 PM