User Manual

ASUS ASMB9-iKVM
4-73
Name Type ReadOnly Description
UpperThreshold
Fatal(C)
Number True The value of this property shall indicate the CurrentReading is above the
normal range and is fatal. Units shall use the same units as the related
ReadingVolts property.
LowerThreshold
NonCritical(C)
Number True The current reading is below the normal range but is not critical. Units
shall use the same units as the related ReadingVolts property.
LowerThreshold
Critical(C)
Number True The current reading is below the normal range but is not yet fatal. Units
shall use the same units as the related ReadingVolts property.
LowerThreshold
Fatal(C)
Number True The value of this property shall indicate the CurrentReading is below the
normal range and is fatal. Units shall use the same units as the related
ReadingVolts property.
MinReadingRange Number True The lowest possible value for CurrentReading. Units shall use the same
units as the related ReadingVolts property.
Northbound is supported but Southbound needs platform
specific porting.
MaxReadingRange Number True The highest possible value for CurrentReading. Units shall use the
same units as the related ReadingVolts property.
Northbound is supported but Southbound needs platform
specific porting.
PhysicalContext(C) Object True The affected device or region within the chassis to which
this voltage measurement applies.(Refer to Table 36
ThermalPhysicalContextEnum Properties)
This property can be configured through system builder. If
it is not configured then the default value will be set to this
property. i.e., VoltageRegulator
RelatedItem(C) Array True The ID(s) of the resources associated with this Power Limit.
(continued on the next page)
Table 33 PowerSupply Properties
Name Type ReadOnly Description
Name(C) String True The name of the PowerSupply.
PowerSupplyType(C) String True The Power Supply type (AC or DC).
Enum Description
Unknown The power supply type cannot be determined.
AC Alternating Current (AC) power supply.
DC Direct Current (DC) power supply.
ACorDC Power Supply supports both DC or AC.
E16160_ASMB9-iKVM_UM_V3.indb 73E16160_ASMB9-iKVM_UM_V3.indb 73 1/17/2020 2:29:30 PM1/17/2020 2:29:30 PM