RAID configuration and RAID configuration and
RAID configuration and RAID configuration and
RAID configuration and
driver installationdriver installation
driver installationdriver installation
driver installation
6. Restart the system, then press <Ctrl> + <F> to enter the FastBuild
Utility.
7. From the FastBuild Utility main menu, press <5> to display the
Rebuild Array MenuRebuild Array Menu
Rebuild Array MenuRebuild Array Menu
Rebuild Array Menu.
8. Use the arrow keys to select the array with a
Critical Critical
Critical Critical
Critical status, then
press <Enter>.
9. From the
Select Drive to Rebuild Select Drive to Rebuild
Select Drive to Rebuild Select Drive to Rebuild
Select Drive to Rebuild section, use the arrow keys to
highlight the replacement drive, then press <Enter>.
All data on the replacement drive will be overwritten with mirrored
information from the existing array drive. A progress bar indicates the
duplicating process.
10. When finished, exit the utility, then restart the system.