Range 1 90V 115V 140V
Range 2 180V 230V 264V
Input Frequency Range 43 Hz to 66 Hz
Maximum Input ac Current 5A max at 115Vac
3A max. at 230Vac, maximum load
Inrush Current 90A cold start
120A warm start
Efficiency 65% min. at nominal input,
maximum load
Load Range Regulation Ripple
+5V 1.5A 25.0A -5% +5% 50mV
p-p
+12V 0.2A 8.0A -5% +5% 120mV
p-p
-12V 0A 0.8A -10% +10% 120mV
p-p
+5Vsb 0A 2.0A -5% +5% 50mV
p-p
+3V3 0A 14.0A -5% +5% 50mV
p-p
+5V 6.5V
+12V 15.6V
+3.3V 4.3V
4.2