User Guide

Table Of Contents
53987 Rev. 3.01 June 2016
AMD-RAIDXpert2 User Guide
Chapter 7
Troubleshooting
93
7.5 Disk Related Errors
Table 38. Disk Errors
Section 7.5.1, Troubleshooting Disks, on page 93.
Table 38. Disk Errors
Possible Causes
Additional Information
Corrective Actions
A disk has been removed from
an array
See Section 7.5.1,
Troubleshooting Disks, on page
93.
A disk is not visible in the BIOS
Configuration Utility or is offline
A disk is highlighted red at the
BIOS Configuration Utility
The disk has failed.
Depending on the RAID level of
the array, data might be lost.
RAIDXpert2 cannot
communicate with the spare
The dedicated spare is not visible
in the BIOS Configuration Utility
or is offline.
The disk cannot be initialized
Only disks that are Ready can be
initialized.
CAUTION: When a disk is
initialized, all data on the disk is
lost.
Ensure the disk is not already
a member of an array.
Ensure the disk is still
assigned as a global or
dedicated spare.
Ensure the disk is reporting a
Ready state.
7.5.1 Troubleshooting Disks
Perform the following actions when there may be a problem with a disk.
Ensure there is no damage to the system’s backplane.
Ensure all cables are installed correctly.
Ensure the disk is seated correctly in the backplane or bay and the latch is secured.
Reinsert the disk.
Replace the disk.
After reconnecting, reseating, reinserting, or replacing a disk:
Perform a rescan.
Initialize the disk.
CAUTION: When a disk is initialized, all data on the disk is lost.