User Guide
Table Of Contents
- AMD -RAIDXpert2 User Guide
- Contents
- List of Tables
- Revision History
- Preface
- Chapter 1 Safety Precautions
- Chapter 2 Getting Started
- Chapter 3 Arrays, Disks and RAID Levels
- 3.1 Understanding Arrays
- 3.2 RAID Levels
- 3.3 Array States
- 3.4 Creating Arrays: Future Expansion
- 3.5 Expanding Disk Capacity Online: Using OCE (Supported by RAIDXpert2 Plus)
- 3.6 Migrating RAID Levels Online: Using ORLM (Supported by RAIDXpert2 Plus)
- 3.7 Array Tasks: Starting and Stopping Tasks
- 3.8 Understanding Disks
- 3.9 Rescanning Disks for Changes in State
- 3.10 Sparing Options: Disks and Arrays
- 3.11 Dedicated Sparing
- 3.12 Global Sparing
- 3.13 RAID Performance Considerations
- 3.14 RAID Reliability Considerations
- 3.15 Flexibility and Expansion Considerations
- 3.16 Multiple RAID Levels
- 3.17 RAIDABLE Arrays
- Chapter 4 BIOS Configuration Utility
- 4.1 When to Use the AMD-RAID Controller BIOS Configuration Utility
- 4.2 Access the AMD-RAID Controller BIOS Configuration Utility
- 4.3 Understanding the Color Code in the BIOS Configuration Utility
- 4.4 Initialize Disks
- 4.5 Create Arrays
- 4.6 Delete Arrays
- 4.7 Swap Arrays
- 4.8 Manage Spares
- 4.9 View Disk Details
- 4.10 View Array Details
- 4.11 Rescan All Channels
- 4.12 Change the Controller Options
- 4.13 Continue Booting from the BIOS Configuration Utility
- Chapter 5 Software Installation
- 5.1 System Setup Process Overview
- 5.2 Before You Begin
- 5.3 Copying AMD-RAID Drivers to Removable Storage
- 5.4 Pre-installation steps
- 5.5 Installing AMD-RAID drivers
- 5.5.1 Installing AMD-RAID Drivers while Installing Microsoft® Windows®
- 5.5.2 Installing AMD-RAID Drivers While Installing Linux® Operating System
- 5.5.2.1 Installing the AMD-RAID BIOS Drivers During a Red Hat Enterprise Linux® 7.2 64 bit (RHEL) Installation
- 5.5.2.2 Installing the AMD-RAID BIOS Drivers during a Supported Ubuntu Desktop Installation
- 5.5.2.3 Install the AMD-RAID UEFI Drivers during a RHEL 7.2 64 bit Linux® Installation
- 5.5.2.4 Installing the AMD-RAID UEFI Drivers during a Supported Ubuntu Desktop Installation
- 5.6 Installing the AMD RAIDXpert2 Management Suite for Microsoft® Windows®
- 5.7 Installing the AMD RAIDXpert2 Management Suite for Linux®
- 5.8 Installing the AMD RAIDXpert2 Graphical User Interface (GUI)
- Chapter 6 AMD RAIDXpert2 Graphical User Interface (GUI)
- 6.1 Start RAIDXpert2
- 6.2 Password Protection
- 6.3 Help and About Windows®
- 6.4 Reviewing the RAIDXpert2 GUI
- 6.5 Working with Disks
- 6.6 Working with Arrays
- 6.6.1 Create and Format Arrays
- 6.6.2 Name Arrays
- 6.6.3 Transform Arrays (Supported by RAIDXpert2 Plus)
- 6.6.4 Restore (Rebuild) Arrays
- 6.6.5 Prepare to Physically Remove an Array
- 6.6.6 Delete Arrays
- 6.6.7 Change Cache Settings for Arrays
- 6.6.8 Change the Priority Level of a Task
- 6.6.9 Interrupt, Cancel, or Resume a Task
- 6.6.10 Check for Consistency
- 6.6.11 Schedule a Consistency Check
- 6.6.12 Scan an Array in the Background
- 6.6.13 Add or Remove Dedicated Spares
- 6.6.14 Add or Remove Global Spares
- 6.6.15 Hide an Array
- 6.6.16 Secure Erase
- 6.7 Working with Views
- 6.8 Working with Options
- 6.9 Add Space Using a RAIDABLE Array
- Chapter 7 Troubleshooting
- Chapter 8 Software License: EULA
- Chapter 9 rcadm Command Line Interface Tool
- Appendix A rcadm.efi Information

53987 Rev. 3.01 June 2016
AMD-RAIDXpert2 User Guide
Chapter 7
Troubleshooting
91
Table 33. An Array is in a Critical State
Possible Causes
Additional Information
Corrective Actions
One or more disks in the
array have failed or been
removed.
Due to the failed disk or disks, the array is no
longer maintaining redundant (mirrored or parity)
data.
The failure of an additional disk results in an
Offline state and lost data.
See Section 7.5.1,
Troubleshooting Disks,
on page 93.
Table 34. An Array is in an Offline State
Possible Causes
Additional Information
Corrective Actions
The array has lost the
maximum allowable disks
per RAID level.
One or more disks have failed.
If the array is non-redundant, the failure of a
single disk causes the array to fail.
If the array is redundant, the failure of two or
more disks causes the array to fail.
The array cannot be restored (rebuilt).
See Section 7.5.1,
Troubleshooting Disks,
on page 93.
Table 35. Cannot Assign a Dedicated Spare to an Array
Possible Causes
Additional Information
Corrective Actions
The RAID level does not
allow dedicated spares.
Dedicated spares cannot be created for
Volume or RAID0 arrays.
Create an array with a different
RAID level and assign a
dedicated spare.
Create a global spare.
The designated disk does
not have sufficient
capacity to be a dedicated
spare
The capacity of the disk selected to be a
dedicated spare must be equal to or
larger than the capacity of the smallest
disk in the array.
Select a different disk.