Table 19. Elements of the Event View Section, Array Status Window
Element
Description
#
The number of the event.
Date
The date and time at which the event occurred.
Event
The RAIDXpert2 Asynchronous Event Notification (AEN) number of the event.
Priority
The notification priority of the event: Low, Informational, Warning, Critical, or Fatal.
Text
A brief description of the event.
6.4.5 Array and Disk Commands
The Array and Disk menus of the Array Status window contain lists of commands. The commands
allow the system user to initiate or modify array- and disk-related tasks.
Not all commands are available for an array or for the system. Availability depends on:
The tasks that can be performed with the system’s license level.
The RAID level of an array. For example, a Consistency Check can be performed only on
arrays at a redundant RAID level.
The remaining capacity of the disk drives. For example, if a system has three disk drives and
large arrays have used all of the capacity on two of the disks, only non-redundant Volume
arrays can be created on the remaining disk. Certain commands are not available with a non-