AIO Pump Control
[Auto] Detects the type of AIO Pump installed and automatically switches
the control modes.
[PWM Mode] Enables the AIO Pump Q-Fan Control feature in PWM mode for
4-pin AIO Pump.
[DC Mode] Enables the AIO Pump Q-Fan Control feature in DC mode for
3-pin AIO Pump.
[Disabled] Disables the Q-Fan Control.
The following items appear only when AIO Pump Control is set to [Auto], [DC mode], or
[PWM mode].
AIO Pump Q-Fan Source
The assigned fan will be controlled according to the selected temperature
source.
Conguration options: [CPU] [MotherBoard] [VRM] [PCH] [T Sensor]
[EXT_Sensor1] [EXT_Sensor2] [EXT_Sensor3] [Multiple Sources]
For T_Sensor and EXT_Sensor1-3, connect a Thermistor cable to one of
these connectors, then tape the other end on a critical component to control its
temperature. An ASUS FAN EXTENSION CARD is required to enable these items.
For Multiple Sources, select up to three temperature sources and the fan will
automatically change based on the highest temperature.
AIO Pump Upper Temperature
Use the <+> or <-> keys to adjust the upper limit of the AIO Pump
temperature. The AIO Pump will operate at the maximum duty cycle when
the temperature source is higher than the limit.
AIO Pump Max. Duty Cycle (%)
Use the <+> or <-> keys to adjust the maximum AIO Pump duty cycle.
When the temperature source reaches the upper limit, the AIO Pump will
operate at the maximum duty cycle.
The AIO Pump Fan max. duty cycle cannot be lower than the AIO Pump Fan min. duty
cycle.
AIO Pump Middle Temperature
Use the <+> or <-> keys to adjust the middle limit of the AIO Pump
temperature.
AIO Pump Middle. Duty Cycle (%)
Use the <+> or <-> keys to adjust the AIO Pump middle duty cycle.
AIO Pump Lower Temperature
Use the <+> or <-> keys to adjust the lower limit of the AIO Pump
temperature. The AIO Pump will operate at the minimum duty cycle when
the temperature is lower than the limit.