ROG STRIX X299-E Gaming BIOS Manual
69
The following items appear only when Water Pump+ Control is set to [Auto], [DC
mode], or [PWM mode].
Water Pump+ Q-Fan Source
The assigned fan will be controlled according to the selected temperature
source.
Conguration options: [CPU] [MotherBoard] [VRM] [PCH] [T Sensor]
[EXT_Sensor1] [EXT_Sensor2] [EXT_Sensor3] [Multiple Sources]
• For T_Sensor and EXT_Sensor1-3, connect a Thermistor cable to one of
these connectors, then tape the other end on a critical component to control its
temperature. An ASUS FAN EXTENSION CARD is required to enable these items.
• For Multiple Sources, select up to three temperature sources and the fan will
automatically change based on the highest temperature.
Water Pump+ Upper Temperature
Use the <+> or <-> keys to adjust the upper limit of the Water Pump+
temperature. The Water Pump+ will operate at the maximum duty cycle
when the temperature source is higher than the limit.
The Water Pump+ upper temperature cannot be lower than the Water Pump+ Fan lower
temperature.
Water Pump+ Max. Duty Cycle (%)
Use the <+> or <-> keys to adjust the maximum Water Pump+ duty cycle.
When the temperature source reaches the upper limit, the Water Pump+
will operate at the maximum duty cycle.
The Water Pump+ Fan max. duty cycle cannot be lower than the Water Pump+ Fan min.
duty cycle.
Water Pump+ Middle Temperature
Use the <+> or <-> keys to adjust the middle limit of the Water Pump+
temperature.
Water Pump+ Middle. Duty Cycle (%)
Use the <+> or <-> keys to adjust the Water Pump+ middle duty cycle.
Water Pump+ Lower Temperature
Use the <+> or <-> keys to adjust the lower limit of the Water Pump+
temperature. The Water Pump+ will operate at the minimum duty cycle
when the temperature is lower than the limit.
Water Pump+ Min. Duty Cycle(%)
Use the <+> or <-> keys to adjust the minimum Water Pump+ duty cycle.
When the temperature source is under the limit, the Water Pump+ will
operate at the minimum duty cycle.