User manual
ASUS 970 PRO GAMING/AURA 2-27
Chassis Fan Min. Duty Cycle(%) [60]
Use the <+> and <‑> keys to adjust the minimum chassis fan duty cycle. The values
range from 60% to 100%. When the chassis temperature is under 40°C, the chassis
fan will operate at the minimum duty cycle.
Water Pump Control [Disabled]
[Disabled] Disable the Water Pump control feature.
[DC mode] Enable the Water Pump control in DC mode for 3‑pin chassis fan.
[PWM mode] Enable the Water Pump control in PWM mode for 4‑pin chassis fan.
The following items appear only when you set the Water Pump Control to [DC mode] or
[PWM mode].
PUMP Fan Speed Low Limit [600 RPM]
This item allows you to disable or set the water pump warning speed.
Conguration options: [Ignore] [100 RPM] [200 RPM] [300 RPM] [400 RPM] [500 RPM] [600
RPM]
Water Pump Profile [Standard]
This item allows you to set the appropriate performance level of the chassis fan.
[Standard] Sets to [Standard] to make the chassis fan automatically adjust depending
on the chassis temperature.
[Silent] Sets to [Silent] to minimize the fan speed for quiet chassis fan operation.
[Turbo] Sets to [Turbo] to achieve maximum chassis fan speed.
[Manual] Sets to [Manual] to assign detailed fan speed control parameters.
The following items appear only when you set Water Pump Profile to [Manual].
Water Pump Upper Temperature [70]
Use the <+> and <‑> keys to adjust the upper limit of the chassis temperature. The
values range from 40°C to 90°C.
Water Pump Lower Temperature [40]
Displays the lower limit of the chassis temperature.
Water Pump Max. Duty Cycle(%) [60]
Use the <+> and <‑> keys to adjust the maximum chassis fan duty cycle. The values
range from 60% to 100%. When the chassis temperature reaches the upper limit, the
chassis fan will operate at the maximum duty cycle.
Water Pump Min. Duty Cycle(%) [60]
Use the <+> and <‑> keys to adjust the minimum chassis fan duty cycle. The values
range from 60% to 100%. When the chassis temperature is under 40°C, the chassis
fan will operate at the minimum duty cycle.