User manual
The following items appear only when you set Extension Fan 1/2/3 Profile to [Manual].
Extension Fan 1/2/3 Upper Temperature [70]
Use the <+> or <‑> keys to adjust the upper limit of the extension fan temperature. The
values range from 20°C to 75°C.
Extension Fan 1/2/3 Max. Duty Cycle(%) [100]
Use the <+> or <‑> keys to adjust the maximum extension fan duty cycle. The values
range from 60% to 100%. When the chassis temperature reaches the upper limit, the
extension fan will operate at the maximum duty cycle.
Extension Fan 1/2/3 Middle Temperature [45]
Use the <+> or <‑> keys to set the value for Extension Fan Middle Temperature.
Extension Fan 1/2/3 Middle Duty Cycle(%) [60]
Use the <+> or <‑> keys to adjust the extension fan middle duty cycle. The values
range from 60% to 100%.
Extension Fan 1/2/3 Lower Temperature [40]
Use the <+> or <‑> keys to adjust the extension fans’ lower temperature. The values
range from 0°C to 75°C.
Extension Fan 1/2/3 Min. Duty Cycle(%) [60]
Use the <+> or <‑> keys to adjust the minimum extension fan duty cycle. The values
range from 60% to 100%. When the CPU temperature is under the lower limit, the
extension fan operates at the minimum duty cycle.
Allow Fan Stop [Disabled]
This function allows the fan to run at 0% duty cycle when the temperature of the source
is dropped below the lower temperature. Conguration options: [Disabled] [Enabled]
2.7.6 Anti Surge Support [On]
This item allows you to enable or disable the Anti Surge function.
Conguration options: [On] [Off]
2‑38 Chapter 2: Getting started